HP XP Continuous Access Software User Manual
Page 217

Pair status
Description
Corrective action
Failure occurred at a local
array port.
Repair the port status on the local array.
Failure occurred at a remote
array port.
Repair the port status on the remote array.
After that, delete the path using the Delete
Path or Delete DKC command, and add the
path and remote array again using the Add
Path or Add DKC command.
Failure occurred in the path
relay equipment.
Repair the path relay equipment. After that,
delete the path using the Delete Path or
Delete DKC command, and add the path
and remote array again using the Add Path
or Add DKC command.
Logical Blockade
Connection cable is physically
broken.
Replace the broken cable. After that, delete
the path using the Delete Path or Delete
DKC command, and add the path and
remote array again using the Add Path or
Add DKC command.
Program Error
Program error detected.
Delete the path using the Delete Path or
Delete DKC command, and add the path
and remote array again using the Add Path
or Add DKC command.
Path was not established.
Delete the failed path. You might need
to change the minimum paths setting or
delete the remote array to delete the path.
After deletion finishes, add the path and
remote array using the Add Path or Add
DKC command.
Continuous Access XP Journal user guide