HP XP Continuous Access Software User Manual
Page 216

Pair status
Description
Corrective action
Invalid Port
Specified port is not
configured as an initiator
port, or this path already
exists.
Ensure that the topology settings of the
local and remote array ports are correct.
Ensure that you entered the correct remote
array S/N and path parameters (for
example, local array port, remote array
port, and controller ID). After that, delete
the failed path. You might need to change
the minimum paths setting or delete the
remote array to delete the path. After
deletion finishes, add the path and the
remote array again.
Port number invalid
Specified port number is
invalid. The cable is not
connected to the specified
port.
Delete the failed path. Check the specified
port number or cable connection, and retry.
Communication error
Timeout error occurred in the
fibre path between the local
and remote arrays.
Delete the failed path, and retry.
Pair-Port Number Mismatch
Specified port in the
remote array is physically
disconnected from the local
array.
Ensure that you specified the correct remote
array port. Correct the port number if
necessary.
Ensure that the local and remote arrays
are connected by cables to each other. If
the arrays are not by cables, and retry the
operation.
Ensure that the topology settings of ports on
the local and remote arrays are correct.
Pair-Port Type Mismatch
Specified remote array port
is not configured as an RCU
target port.
Ensure that the remote array port is
configured as an RCU target port.
Communication Failed
Local array is connected to
the remote array successfully,
but a logical communication
timeout occurred.
Ensure that the remote array port and
network relay devices (for example, cables
and switches) are properly configured and
functioning.
216