HP StorageWorks MSA 2.8 SAN Switch User Manual
Page 84

Firmware Download
84
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
By default,
firmwaredownload
will do a full install of the whole firmware
regardless of whether a package is already current or not. In Incremental Install
Upgrade Mode, the names of packages are compared to what is already installed
on the switch; only the packages that are different from those already stored or not
on the switch yet are installed.
Use the -i option to do an incremental firmware download.
Downloading Firmware to a Single CP on a Core Switch 2/64
Though it is possible to download firmware to one CP at a time, is not
recommended. We recommend that both CPs be upgraded at the same time so
they are consistent.
Note:
This is the procedure to follow if your
Core Switch 2/64
is running version
4.0.0c or less.
The following procedure enables single mode on aCore Switch 2/64 series switch.
Single Mode allows a user to:
■
Upgrade to a single CP on aCore Switch 2/64 switch
■
Select a full-install, auto-reboot, and auto-commit (only the "-s" option is
required on the command line).
■
Upgrade a Core Switch 2/64 that is running v4.0.0c or less.
To enable Single Mode on a Core Switch 2/64:
1. Telnet in to the Core Switch 2/64 as admin.
Example
Note:
In this example, the Active CP is CP1, and the Standby CP is CP0.
2. Execute the
hashow
command to determine which CP is the Active and
which is the Standby.
switch:admin>