Troubleshooting

221

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Test a Port’s External Transmit and Receive Path

1. Log into the switch as admin.

2. Enter the

crossporttest

command with the following operand.

(This is a partial list. Refer to the HP StorageWorks Fabric OS Version
3.1.x/4.1.x Reference Guide
for more information).

switch:admin> setdbg "DIAG", 2

switch:admin> spinfab 3,0,3

spinFab running...

port 1 Rx 1 million frames.

port 0 Rx 1 million frames.

port 2 Rx 1 million frames.

port 3 Rx 1 million frames.

port 1 Rx 2 million frames.

port 0 Rx 2 million frames.

port 2 Rx 2 million frames.

port 3 Rx 2 million frames.

port 1 Rx 3 million frames.

port 0 Rx 3 million frames.

port 2 Rx 3 million frames.

port 3 Rx 3 million frames.

spinFab: Completed 3 megs, status: passed.

port 0 test status: 0x00000000 -- passed.

port 1 test status: 0x00000000 -- passed.

port 2 test status: 0x00000000 -- passed.

port 3 test status: 0x00000000 -- passed.

switch:admin>

[-nframes count]

Specify the number of frames to send.

[-lb_mode mode]

Select the loopback point for the test.