HP StorageWorks MSA 2.8 SAN Switch User Manual
Page 60

Basic Switch Management
60
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
— Enter the number of temperature warnings required to change the switch
status to DOWN and click Enter.
— Enter the number of temperature warnings required to change the switch
status to MARGINAL and click Enter.
— Enter the number of fan speed warnings required to change the switch
status to DOWN and click Enter.
— Enter the number of fan speed warnings required to change the switch
status to MARGINAL and click Enter.
— Enter the number of port down warnings required to change the switch
status to DOWN and press the Enter.
— Enter the number of port down warnings required to change the switch
status to MARGINAL and click Enter.
— Enter the number of ISLstatus down warnings required to change the
switch status to DOWN and click Enter.
— Enter the number of ISLstatus down warnings required to change the
switch status to MARGINAL and click Enter.
Example:
switch:admin> switchstatuspolicyset
To change the overall switch status policy parameters
The current overall switch status policy parameters:
Down Marginal
----------------------------------
FaultyPorts 2 1
MissingSFPs 0 0
PowerSupplies 2 1
Temperatures 2 1
Fans 2 1
PortStatus 0 0
ISLStatus 2 1
Note that the value, 0, for a parameter, means that i
NOT used in the calculation.
** In addition, if the range of settable values in the
** the policy parameter is NOT applicable to the switch