beautypg.com

HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 60

background image

Basic Switch Management

60

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

— Enter the number of temperature warnings required to change the switch

status to DOWN and click Enter.

— Enter the number of temperature warnings required to change the switch

status to MARGINAL and click Enter.

— Enter the number of fan speed warnings required to change the switch

status to DOWN and click Enter.

— Enter the number of fan speed warnings required to change the switch

status to MARGINAL and click Enter.

— Enter the number of port down warnings required to change the switch

status to DOWN and press the Enter.

— Enter the number of port down warnings required to change the switch

status to MARGINAL and click Enter.

— Enter the number of ISLstatus down warnings required to change the

switch status to DOWN and click Enter.

— Enter the number of ISLstatus down warnings required to change the

switch status to MARGINAL and click Enter.

Example:

switch:admin> switchstatuspolicyset

To change the overall switch status policy parameters

The current overall switch status policy parameters:

Down Marginal

----------------------------------

FaultyPorts 2 1

MissingSFPs 0 0

PowerSupplies 2 1

Temperatures 2 1

Fans 2 1

PortStatus 0 0

ISLStatus 2 1

Note that the value, 0, for a parameter, means that i

NOT used in the calculation.

** In addition, if the range of settable values in the

** the policy parameter is NOT applicable to the switch