Link failure, Possible causes for link failure, Switch state – HP StorageWorks MSA 2.8 SAN Switch User Manual
Page 229: Table 19: switchstate and actions to take, 19 switchstate and actions to take

Troubleshooting
229
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
Link Failure
A link failure occurs when a server or storage is connected to a switch, but the link
between the server/storage and the switch does not come up. This prevents the
server/storage from communicating through the switch.
Possible Causes for Link Failure
If the
switchshow
command and/or the LED lights indicate that the link has
not come up properly, follow the steps for one or more of the areas indicated
below.
A link failure can be caused by one of the following reasons:
■
, page 229
■
,
■
■
Link Initialization Failure (Loop)
■
Port Has Come Up in a Wrong Mode
Switch State
1. Enter the
switchshow
command.
2. Check the switchState entry in the
switchshow
command output.
3. Use the following list of switch states to determine the next step:
Table 19: SwitchState and Actions to Take
SwitchState
Action
Online
The state of the switch is ok. Move on to check
the “
Offline
Enable the switch by entering the switchenable
command.
Testing
Wait for the switch to complete its test.
Faulty
Check the condition of the switch. Enter the
switchStatusShow
and
errShow
or
errDump
commands and identify the
malfunctioning parts. Refer to the
HP
StorageWorks Fabric OS Version 3.1.x/4.1.x
Reference Guide
for more information.