Detailed zone merge correction procedure, Verify fabric merge problem, Edit zone config members – HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 208

background image

Troubleshooting

208

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

2. Enter the

cfgDisable

command.

3. Enter the

cfgClear

command.

Caution:

Be careful when using the

cfgclear

command because you can

inadvertently delete the Zone configuration in the fabric. Make sure you are

deleting the “incorrect” configuration.

4. Enter the

switchdisable

command.

5. Enter the

switchenable

command. This automatically evokes the

cfgSave

command.

The two fabrics will be remerged.

6. See “

Detailed Zone Merge Correction Procedure

” on page 208 for more

detailed troubleshooting instructions.

Detailed Zone Merge Correction Procedure

For more information regarding Zoning, refer to the

HP StorageWorks Zoning

Version 3.1.x/4.1.x User Guide

.

For detailed troubleshooting of zone merge issues, follow the steps below.

Verify Fabric Merge Problem

1. Enter the

switchshow

command at the command line to validate that the

segmentation is due to a zone issue.

2. See “

Zoning Setup Issues

” on page 206 to view the different types of zone

discrepancies.

Edit Zone Config Members

3. Log into one of the segmented Fabrics as admin.

4. Enter the

cfgshow

command.

Typing the “*” symbol after the command displays list of all config names.

5. Print the output from the

cfgShow

command.

6. Start another Telnet session and log into the next fabric as admin.

7. Run the

cfgShow

command.

8. Print the output from the

cfgShow

command.