Monitoring the power supply status – HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 188

background image

Diagnostics and Status

188

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Note:

The number of fans and valid range for RPMs varies depending on the type of

switch. For more information, refer to the particular hardware reference manual for

your switch.

Monitoring the Power Supply Status

To display the power supply status of a switch:

1. Log into the switch as the admin user.

2. Enter the

psshow

command at the command line. The possible values for

power supply status are:

OK -

Power supply present and functioning correctly.

absent -

Power supply not present.

faulty -

Power supply present but faulty (no power cable, power switch

turned off, fuse blown, or other internal error).

After the status line, a power supply identification line may be shown. If present,
this line contains manufacture date, part numbers, serial numbers, and other
identification information.

The following example displays the power supply status using the

psshow

command.

Example:

switch:admin> psshow

Power Supply #1 is OK

DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000089

Power Supply #2 is OK

DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000132

Power Supply #3 is absent

Power Supply #4 is OK

DELTA DPS-1001AB-1E 23000000601 S1 IXD0111000117

switch:admin>