beautypg.com

Resizing the persistent error log – HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 169

background image

Diagnostics and Status

169

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Example

The following example shows how to display current error log save level on the
Standby CP for switch 0.The value -s is added to save the Standby CP.

Example

Resizing the Persistent Error Log

To resize the persistent error log of a switch to a new size specified by the operand

number_of_entries

:

1. Log in to the switch as the admin user.

2. At the command line enter the

errnvlogsizeset

command.

The following example shows how to resize the persistent error log to 1500
entries.

Example

switch:admin> errsavelvlshow

Current message save level is = 3

switch:admin>

switch:admin> errsavelvlshow -s 0

Current message save level is = 3

switch:admin>

switch:admin> errnvlogsizeset 1500

Persistent error log is resized to store 1500 entries

switch:admin>