beautypg.com

HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 178

background image

Diagnostics and Status

178

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

.

For more information, refer to the

switchshow

command in the HP

StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide.

The following example shows the

switchshow

command output on a Core

Switch 2/64.

Example

port 0: id N1 Online E-Port 10:00:00:60:69:11:fc:08 "fmgr129"
(downstream

)

port 1: id N2 Online E-Port 10:00:00:60:69:90:03:1f "fmgr137"
(upstream)

port 2: -- N2 No_Module

port 3: -- N2 No_Module

port 4: -- N2 No_Module

port 5: -- N2 No_Module

port 6: id N2 No_Light

port 7: id N2 No_Light

switch:admin>

switch:admin> switchshow

switchName: switch61

switchType: 10.1

switchState: Offline

switchRole: Disabled

switchDomain: 97 (unconfirmed)

switchId: fffc61

switchWwn: 10:00:00:60:69:80:04:5a

switchBeacon: OFF

blade1 Beacon: OFF

blade3 Beacon: OFF

Area Slot Port Gbic Speed State

=====================================

0 1 0 id N2 No_Light Disabled