Troubleshooting

233

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

E_port

If the opposite side is not another switch, the link has come up in a

wrong mode. Check the output from the

portLogShow

/

PortLogDump

commands and identify the link

initialization stage where the initialization procedure went wrong.

F_port

If the opposite side of the link is a fabric device, the link has come

up in a wrong mode. Check the output from the

portLogShow

or

PortLogDump

commands.

G_port

The port has not come up as an E_port or F_port. Check the output

from the

portLogShow

or

PortLogDump

commands and

identify the link initialization stage where the initialization

procedure went wrong.

L_port

If the opposite side is

not

a loop device, the link has come up in a

wrong mode. Check the output from the

portLogShow

or

PortLogDump

commands and identify the link initialization stage

where the initialization procedure went wrong.

Table 21: SwitchShow Output and Suggested Action (Continued)

Output

Suggested Action