beautypg.com

HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 226

background image

Troubleshooting

226

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

2. Disable the switch by entering

switchdisable

at the command line.

3. Enter

portloopbacktest [passcount]

to set all ports for parallel

loopback.

Refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide
for detailed information about the optional operand.

4. Transmit frame F through port N.

5. Pick up the frame from the same port N.

6. Check the following statistic error counters for non-zero values:

ENC_in, CRC_err, TruncFrm, FrmTooLong, BadEOF, Enc_Out,
BadOrdSet, DiscC3

7. Check if the transmit, receive, or class 3 receiver counter are stuck at a value.

8. Check if the number of frames transmitted is not equal to the number of

frames received.

9. Repeat steps 3 through 7 for all ports present until:

— The number of frames (or passCount) requested is reached.

— All ports are marked as bad.

Possible Errors

One or more of the following errors may appear if failures are detected. Refer to
the HP StorageWorks Diagnostic and System Error Message Version 3.1.x/4.1.x
Reference Guide
to find details and actions for any errors that appear.

DIAG-INIT

DIAG-PORTDIED

DIAG_XMIT

DIAG-TIMEOUT

DIAG_ERRSTAT

DIAG-STATS

DIAG-DATA