beautypg.com

Point-to-point initialization failure, Port has come up in a wrong mode, Table 21: switchshow output and suggested action – HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 232: 21 switchshow output and suggested action

background image

Troubleshooting

232

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Point-to-Point Initialization Failure

1. Confirm that the port is active

If a Fabric device or another switch is connected to the switch, the switch port
must be active.

a.

Enter the

portLogShow

or

portLogDump

commands.

b.

Verify that the State Change Notification (SCN) code is 1. An SCN of 1
indicates that the port is active.

Example:

2. Skip over the loop initialization phase

After becoming an active port, the port becomes an F_Port or an E_Port,
depending on the device on the opposite side. If the opposite device is a Fabric
device, the port becomes an F_Port. If the opposite device is another switch,
the port becomes an E_Port.

Some Fabric devices have problem with loop initialization. If this is the case,
perform the following step:

— Enter the

portCfgGport

command.

Port Has Come Up in a Wrong Mode

1. Enter the

switchShow

command.

2. Check the comment fields for the following output and follow the suggested

actions.

13:25:12.506 PORT scn 1

Table 21: SwitchShow Output and Suggested Action

Output

Suggested Action

Disabled

Enter the

portEnable

command.

Bypassed

Check the output from the

portLogShow

or

portLogDump

commands and identify the link initialization stage where the

initialization procedure went wrong.

Loopback

Check the output from the

portLogShow

/

PortLogDump

commands and identify the link initialization stage where the

initialization procedure went wrong.