beautypg.com

Procedures for updating the core pid format, Basic update procedures, Bric (see – HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 154: Procedures for, Updating the core pid format

background image

Updating Switches to the Core PID Addressing

154

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Procedures for Updating the Core PID Format

The following sections present basic procedures for update the Core PID format
and detailed procedures for HP/UX and AIX.

Basic Update Procedures

This process should be executed as part of the overall online or offline update
process. However, it may be implemented in a stand-alone manner on a
non-production fabric on a switch that has not yet joined a fabric.

1. Ensure that all switches in the fabric are running Fabric OS versions that

support the new addressing mode. The recommended firmware versions are:
2.6.0c or later for StorageWorks 1 Gb SAN switches, 3.0.2g or later for SAN
Switch 2/8 EL and SAN Switch 2/16 switches, and 4.0.2x or later for SAN
Switch 2/32 and Core Switch 2/64 switches.

Note:

All switches running any version of Fabric OS 4.x are shipped with the Core

Switch PID Format enabled, so it is not necessary to perform the PID format change on

these switches.

2. Telnet into one of the switches in the fabric.

3. Disable the switch by entering the

switchdisable

command.

4. Enter the

configure

command (the configure prompts display

sequentially).

5. Enter

“y”

after the “Fabric parameters” prompt.

6. Enter “

1

” at the “Core Switch PID Format” prompt.

7. Complete the remaining prompts or press Ctrl+D to accept the remaining

settings without completing all the prompts.

8. Repeat steps 2 through 7 for the remaining switches in the fabric.

9. Re-enable the switch by entering the

switchenable

command.