Basic Switch Management

59

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Example:

Configuring the Policy Threshold Values

To set the switch status policy threshold values:

1. Log into the switch as the admin user.

2. Enter the

switchstatuspolicyset

command at the command line.

First, the current switch status policy parameter values are displayed, then you
are prompted to enter values for each DOWN and MARGINAL threshold
parameter:

— Enter the number of faulty ports required to change the switch status to

DOWN and click Enter.

— Enter the number of faulty ports required to change the switch status to

MARGINAL and click Enter.

— Enter the number of missing GBICs required to change the switch status

to DOWN and click Enter.

— Enter the number of missing GBICs required to change the switch status

to MARGINAL and click Enter.

— Enter the number of bad Power Supply warnings required to change the

switch status to DOWN and click Enter.

— Enter the number of bad Power Supply warnings required to change the

switch status to MARGINAL and click Enter.

switch:admin> switchstatuspolicyshow

The current overall switch status policy parameters:

Down Marginal

----------------------------------

FaultyPorts 2 1

MissingSFPs 0 0

PowerSupplies 2 1

Temperatures 2 1

Fans 2 1

PortStatus 0 0

ISLStatus 2 1

switch:admin>