Switch status policies, Viewing the policy threshold values – HP StorageWorks MSA 2.8 SAN Switch User Manual
Page 58
Basic Switch Management
58
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
Switch Status Policies
For detailed information about setting policy parameters, refer to the HP
StorageWorks Fabric Watch Version 3.1.x/4.1.x User Guide.
The policy parameter determines the number of failed or non-operational units for
each contributor that will trigger a status change in the switch.
Each parameter can be adjusted so that a specific threshold must be reached
before that parameter changes the overall status of a switch to MARGINAL or
DOWN. For example, if the FaultyPorts DOWN parameter is set to 3, the status of
the switch will change if 3 ports fail. Only one policy parameter needs to pass the
MARGINAL or DOWN threshold to change the overall status of the switch.
There are seven parameters that determine the status of a switch:
■
Number of faulty ports
■
Missing GBICs
■
Power supply status
■
Temperature in enclosure
■
Fan speed
■
Port status
■
ISL status
Viewing the Policy Threshold Values
To view the switch status policy threshold values:
1. Log into the switch as the admin user.
2. Enter the
switchstatuspolicyshow
command at the command line.