beautypg.com

HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 224

background image

Troubleshooting

224

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

8. Determine if any of the following statistic error counters are non-zero:

ENC_in, CRC_err, TruncFrm, FrmTooLong, BadEOF, Enc_out,
BadOrdSet, DiscC3.

9. Determine if the transmit, receive, or class 3 receiver counters are stuck at a

value.

10. Determine if the number of frames transmitted is not equal to the number of

frames received.

11. Repeat steps 3 through 11 for all L-ports present until:

a.

the number of frames requested is reached

b.

all ports are marked bad

12. Look for errors. See the following list for possible errors.

Possible Errors

One or more of the following errors may appear if failures are detected. Refer to
the HP StorageWorks Diagnostic and System Error Message Version 3.1.x/4.1.x
Reference Guide
to find details and actions for any errors that appear.

DATA

INIT

PORT_DIED

EPI1_STATUS_ERR

ERR_STAT

ERR_STATS_2Long

ERR_STATS_BADEOF

ERR_STATS_BADOF
ERR_STATS_C3DISC

ERR_STATS_CRC

ERR_STATS_ENCIN

ERR_STATS_ENCOUT

ERR_STATS_TRUNC

ERR_STAT_2LONG

ERR_STAT_BADEOF

ERR_STAT_BADOS