beautypg.com

Marginal links, Confirming the problem – HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 234

background image

Troubleshooting

234

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Marginal Links

A marginal link involves the connection between the switch and the edge device.
Isolating the exact cause of a marginal link involves analyzing and testing many of
the components that make up the link: switch port, switch SFP, cable, the edge
device, and the edge device SFP.

Confirming the Problem

The following steps provide a brief overview of possible steps to troubleshoot a
marginal link.

1. Enter the

portErrShow

command.

Example:

switch:admin> porterrshow

frames enc crc too too bad enc disc link loss loss frjt fbsy

tx rx in err shrt long eof out c3 fail sync
sig=====================================================================

0: 22 24 0 0 0 0 0 1.5m 0 7 3 0 0 0

1: 22 24 0 0 0 0 0 1.2m 0 7 3 0 0 0

2: 0 0 0 0 0 0 0 0 0 0 0 0 0 0

3: 0 0 0 0 0 0 0 0 0 0 0 0 0 0

4: 149m 99m 0 0 0 0 0 448 0 7 6 0 0 0

5: 149m 99m 0 0 0 0 0 395 0 7 6 0 0 0

6: 147m 99m 0 0 0 0 0 706 0 7 6 0 0 0

7: 150m 99m 0 0 0 0 0 160 0 7 5 0 0 0

8: 0 0 0 0 0 0 0 0 0 0 0 0 0 0

9: 0 0 0 0 0 0 0 0 0 0 0 0 0 0

10: 0 0 0 0 0 0 0 0 0 0 0 0 0 0

11: 0 0 0 0 0 0 0 0 0 0 0 2 0 0

12: 0 0 0 0 0 0 0 0 0 0 0 2 0 0

13: 0 0 0 0 0 0 0 0 0 0 0 2 0 0

14: 0 0 0 0 0 0 0 0 0 0 0 2 0 0

15: 0 0 0 0 0 0 0 0 0 0 0 0 0 0

32: 0 0 0 0 0 0 0 0 0 0 0 0 0 0

33: 0 0 0 0 0 0 0 0 0 0 0 0 0 0