beautypg.com

HP StorageWorks MSA 2.8 SAN Switch User Manual

Page 159

background image

Updating Switches to the Core PID Addressing

159

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

rmdev -Rdl fcs0

7. Log into each switch in the fabric.

8. Issue the

switchdisable

command.

9. Issue the

configure

command and change the Core Switch PID Format to

1.

10. Issue the

configenable [effective_zone_configuration]

command. For example:

configenable my_config

11. Issue the

switchenable

command. Enable the core switches first, then the

edges.

12. Rebuild the device entries for the affected fabric using the

cfgmgr

command. For example:

cfgmgr –v

Note:

This command may take several minutes to complete.

13. If you are not using multi-pathing software, vary on the disk volume groups.

The proper usage would be

varyonvg <volume_group_name>

. For

example:

varyonvg datavg

14. If you are not using multi-pathing software, mount all devices again and

restart I/O. For example:

mount /mnt/jbod

15. If you are using multi-pathing software, re-enable the affected path.

16. Repeat for all fabrics.