beautypg.com

GW Instek PPH-1503 User Manual

Page 98

background image

PPH-1503 User Manual

98

Command

:SENSe[1]:PCURrent:AVERage?

Function

Returns the average number for pulse current
measurement.

Example

:SENSe:PCURrent:AVERage?
Returns the average number.

Command

:SENSe[1]:PCURrent:MODE

Function

Sets the pulse current measurement mode.

Description

Name

HIGH: High pulse mode (trigger on the
rising edge).
LOW: Low pulse mode (trigger on the
falling edge)
AVERage: Average pulse measurement.

Example

:SENSe:PCURrent:MODE HIGH
Sets the pulse current measurement mode to
HIGH mode.


Command

:SENSe[1]:PCURrent:MODE?

Function

Queries the pulse current measurement mode.

Example

:SENSe:PCURrent:MODE?
Returns the pulse current measurement mode.


Command

:SENSe[1]:PCURrent:TIME:AUTO

Function

Sets the pulse current integetration time to
automatic.

Example

:SENSe:PCURrent:TIME:AUTO
Sets the pulse current integetration time to
automatic.