beautypg.com

Source commands – GW Instek PPH-1503 User Manual

Page 93

background image

REMOTE CONTROL

93

Source Commands

Command

:[SOURce]:CURRent[:LIMit][:VALue]

Description

Sets the current level.

NRf

0.0000-5.0000

Example

:SOURce:CURRent 1.0005
Sets the current level to 1.0005A.


Command

:[SOURce]:CURRent[:LIMit][:VALue]?

Description

Queries the current limit level.

Example

:SOURce:CURRent?
Returns the current limit level.


Command

:[SOURce]:CURRent[:LIMit]:TYPE

Function

Sets the current limit mode.

Description

LIMit: General limiting mode

TRIP: Output shutdown mode
LIMRELAY|LIMITRELAY:General
limiting mode and external relay output
control mode.
TRIPRELAY: Ouput shutdown mode
and external relay output control mode.

Example

:SOURce:CURRent:TYPE LIMITRELAY
Sets the current limit mode to LIMITRELAY.