beautypg.com

Pph-1503 user manual – GW Instek PPH-1503 User Manual

Page 58

background image

PPH-1503 User Manual

58

External Relay
Connection

There are two ways to connect an external relay to
the unit:

1. Using the the +5VDC relay output to drive an

external relay. Ensure the current doesn’t
exceed 150mA.

+5VDC

OUT

OUT

IN

GND

Power Supply
Relay
Control

Relay

Internal

Source +5VDC

±5%

Protection Diode

Warning: Do not short the 5VDC terminal to the

chasis, earth or to the control port GND, otherwise it
may damage the unit.

2. Using an external power source to drive the

external relay. The voltage of the source cannot
exceed 15V and the current cannot exceed
150mA.

+5VDC

OUT

OUT

IN

GND

Power Supply
Relay
Control

Relay

Internal

Source +5VDC

±5%

Protection Diode

External Source

15VDC Max