OPERATION

91

Note

If the USB drive is not recognized, check to see
that the function settings for F-20 = 1 (page 106). If
not, reinsert the USB flash drive.

3. Configure T-02 (Test Load) to 1~10

(save memory slot)

Page 89

T-02 range

1~10 (t001 ~t010)

4. The script will now be available in the memory

slot the script was saved to.

Note

Error messages: If you load a file that is not
present on the USB drive “Err 002” will be
displayed on the display.

Run Test Script (Manual)

Overview

A test script can be run from one of ten memory
slots.

Steps

1. Before a test script can be run, it

must first be loaded into one of the
10 memory save slots.

Page 90

2. Configure T-01 (Run Test) to 1~10

(save memory slot#)

Page 89

T-01 range

1~10

3. The test script will automatically start to run.