PSW Series User Manual

60

Background

Before setting the power supply to C.V. mode,
ensure:

The output is off.

The load is connected.

Steps

1. Press the Function key. The

Function key will light up.

Function

2. The display should show F-

01 on the top and the
configuration setting for
F-01 on the bottom.

3. Rotate the Voltage knob to change

the F setting to F-03 (V-I Mode
Slew Rate Select).

Voltage

4. Use the Current knob to set the F-

03 setting.

Set F-03 to 0 (CV High Speed
Priority) or 2 (CV Slew Rate
Priority).

Current

F-03

0 = CV High Speed Priority
2 = CV Slew Rate Priority

5. Press the Voltage knob to save the

configuration setting. ConF will be
displayed when successful.

Voltage