PSW Series User Manual

82

OVP/OCP

The master unit can shut down the slave
unit when OVP/OCP is tripped on the
master unit (if the slave connector is wired
for shut down on alarm).

OVP and OCP level is determined by the
master OVP and OCP level. The OVP and
OCP level on the slave unit is ignored.

Remote monitoring

Voltage monitoring (VMON) and current
monitoring (IMON) are only supported on
the master unit.

The VMON voltage represents the total
voltage of the all the serialized units.

Remote Sense

Please see the remote sense chapter for
details, page 68.

External Voltage and Resistance Control

Voltage/Resistance controlled remote
control can only be used with the master
unit.

The full scale voltage (in series) is equivalent
to the maximum external voltage or
resistance.

Slew Rate

The actual slew rate is double that of the
setting slew rate. I.e., A slew rate setting of
60.00V/s is actually 120V/s when in series.

Internal Resistance

The internal resistance is actually twice that
of the setting value.