GW Instek PSW-Series User Manual User Manual
Page 173

APPENDIX
173
Protection Function
Over voltage protection
(OVP)
Setting range
V
3-33
8-88
16-176 20-275 20-880
Setting accuracy
± (2% of rated output voltage)
Over current protection
(OCP)
Setting range
A
5-
118.8
4.05-
44.55
2.16-
23.76
1.35-
14.85
0.432-
4.752
Setting accuracy
± (2% of rated output current)
Over temperature protection
(OTP)
Operation
Turn the output off.
Low AC input protection
(AC-FAIL)
Operation
Turn the output off.
Power limit (POWER LIMIT)
Operation
Over power limit.
Value (fixed)
Approx. 105% of rated output power
Analog Programming and Monitoring
External voltage control
output voltage
Accuracy and linearity: ±0.5% of rated
output voltage.
External voltage control
output current
Accuracy and linearity: ±1% of rated output
current.
External resistor control
output voltage
Accuracy and linearity: ±1.5% of rated
output voltage.
External resistor control
output current
Accuracy and linearity: ±1.5% of rated
output current.
Output voltage monitor
Accuracy
%
±1
±1
±1
±2
±2
Output current monitor
Accuracy
%
±1
±1
±1
±2
±2
Shutdown control
Turns the output off with a LOW (0V to
0.5V) or short-circuit.
Output on/off control
Possible logic selections:
Turn the output on using a LOW (0V to
0.5V) or short-circuit, turn the output off
using a HIGH (4.5V to 5V) or open-circuit.
Turn the output on using a HIGH (4.5V to
5V) or open-circuit, turn the output off
using a LOW (0V to 0.5V) or short-circuit.
CV/CC/ALM/PWR ON/OUT
ON indicator
Photocoupler open collector output;
Maximum voltage 30V, maximum sink
current 8mA.