External Operation and Status Monitoring

Background

The MIL 26 pin connector can also be used to
monitor the status operation and alarm status
of the instrument.

The pins are isolated from the power supply
internal circuitry by photo couplers. Status
Com (Pin 17) is a photo coupler emitter output,
whilst pins 18~22 are photo coupler collector
outputs.

A maximum of 30V and 8mA can be applied to
each pin.
Name and Pin

Description

STATUS COM 17 Common (photo coupler

emitter) for status signals 18,
19, 20, 21 and 22.

CV STATUS

18 Low when CV mode is active.

CC STATUS

19 Low when CC mode is active.

ALM STATUS 20 Low when any of the protection

modes are tripped (OVP,
OCP). Active low.

OUT ON

STATUS

21 Low when the output is on.

PWR OFF

STATUS

22 Active low.

17

Pins 18, 19, 20, 21, 22