PSW Series User Manual

164

CV/CC/ALM/PWR ON/OUT
ON indicator

Photocoupler open collector output;
Maximum voltage 30V, maximum sink
current 8mA.

Front Panel
Display, 4 digits

Voltage accuracy
0.1% +

mV 20

20

100

200

400

Current accuracy
0.1% +

mA 40

20

5

5

2

Indications

GREEN LED's: CV, CC, VSR, ISR, DLY, RMT,
20, 40, 60, 80, 100, %W, W, V, A

RED LED's: ALM

Buttons

Function, OVP/OCP, Set, Test, Lock/Local,
PWR DSPL, Output

Knobs

Voltage, Current

USB port

Type A USB connector

Programming and Measurement (USB, LAN, GPIB)
Output voltage programm-
ing accuracy 0.1% +

mV 10

10

100

200

400

Output current programm-
ing accuracy 0.1% +

mA 30

10

5

5

2

Output voltage
programming resolution

mV 1

2

3

5

14

Output current
programming resolution

mA 1

1

1

1

1

Output voltage measure-
ment accuracy 0.1% +

mV 10

10

100

200

400

Output current measure-
ment accuracy 0.1% +

mA 30

10

5

5

2

Output voltage
measurement resolution

mV 1

2

3

5

14

Output current
measurement resolution

mA 1

1

1

1

1

Series and Parallel Capability
Parallel number

Units

3

3

3

3

3

Series Number

Units

2

2

2

None None