beautypg.com

Internal resistance – GW Instek PSW-Series User Manual User Manual

Page 28

background image

PSW Series User Manual

28

when power is turned off and the load is
disconnected. Without a bleed resistor, power
may remain charged on the filter capacitors for
some time and be potentially hazardous.

In addition, bleed resistors also allow for
smoother voltage regulation of the power
supply as the bleed resistor acts as a minimum
voltage load.

The bleed resistance can be turned on or off
using the configuration settings.

Note

By default the bleed resistance is on. For battery
charging applications, be sure to turn the bleed
resistance off as the bleed resistor can discharge
the connected battery when the unit is off.

Internal Resistance

Background

On the PSW, the internal resistance of the
power supply can be user-defined in software.
(Internal Resistance Setting, page 105). When
the internal resistance is set it can be seen as a
resistance in series with the positive output
terminal. This allows the power supply to
simulate power sources that have internal
resistances such as lead acid batteries.

Internal
Resistance Range

Unit Model

Internal Resistance Range

PSW 30-36

0.000 ~ 0.833Ω

PSW 30-72

0.000 ~ 0.417Ω

PSW 30-108

0.000 ~ 0.278Ω

PSW 80-13.5

0.000 ~ 5.926Ω

PSW 80-27

0.000 ~ 2.963Ω

PSW 80-40.5

0.000 ~ 1.975Ω

PSW 160-7.2

0.000 ~ 22.222Ω

PSW 160-14.4

0.000 ~ 11.111Ω

PSW 160-21.6

0.000 ~ 7.407Ω