ANALOG CONTROL

119

A COM

16 Analog signal common. Connected to the sense-

terminal when remote sense is used. Connected to
the negative output terminal when remote sense is
not used.

STATUS COM

17 Common for status signals 18, 19, 20, 21 and 22.

CV STATUS

18 Turns on when CV mode is active. (photo coupled

open collector output)

CC STATUS

19 Turns on when CC mode is active. (photo coupled

open collector output)

ALM STATUS

20 Turns on when any of the protection modes are

tripped (OVP, OCP) or if a shutdown signal is
input. (photo coupled open collector output)

OUTPUT ON
STATUS

21 Turns on when the output has been turned on.

(photo coupled open collector output)

POWER OFF
STATUS

22 Turns on when the power switch is turned off.

N.C.

23 Not connected

OUT ON/OFF
CONT

24 Turns the output on/off when (default setting) a

low TTL signal is applied. Internally, the circuit is
pulled up to +5V with 10kΩ resistance.

SER SLV IN

25 Series slave input during master-slave series

operation. (30V/80V/160V models only)

N.C.

26 Not connected

External Voltage Control of Voltage Output

Background

External voltage control of the voltage output is
accomplished using the MIL-26 connector on
the rear panel. A voltage of 0~10V is used to
control the full scale voltage of the instrument,
where:

Output voltage = full scale voltage × (external
voltage/10)