beautypg.com

GW Instek PSW-Series User Manual User Manual

Page 80

background image

PSW Series User Manual

80

Master-Slave
Operation

Only operate the power supplies in parallel if
the units are configured correctly.

1. Turn on the master and slave units. The slave

unit(s) will show a blank display.

Master unit

Slave units

2. Operation of all units is controlled

via the master unit. Operation of
the master unit is the same as for a
single unit. See the Basic Operation
chapter.

Page 57.

3. Press the Output key to begin.

Output

Caution

Only operate the power supplies in parallel if using
units of the same model number.

Only a maximum of 3 units can be used in parallel.

Note

The panel controls are disabled on slave units,
including the output key. On slave units only the
Function key can be used to view the current
settings.