beautypg.com

Output terminals psw-250/800 – GW Instek PSW-Series User Manual User Manual

Page 46

background image

PSW Series User Manual

46

Output Terminals PSW-250/800

Background

The high voltage models (PSW 250 and PSW
800 models) use a 9 pin socket for the output
voltage and sense connections. The
corresponding plugs (GW part number 39BT-
50900401 //DECA SwitchLab MC420-38109Z)
should be used to connect the terminals to the
appropriate cable.

Before connecting the output terminals to the
load, first consider whether voltage sense will
be used, the gauge of the cable wiring and the
withstand voltage of the cables and load.

WARNING

Dangerous voltages. Ensure that the power to the
instrument is disabled before handling the power
supply output terminals. Failing to do so may lead
to electric shock.

Please note the wire gauge used and the capacity
of the plug/socket. It may be necessary to wire the
load to a number of terminals to offset the
capacity over a number of terminals.

Output Connector
Overview

When using the output connector make sure
the wires that are used follow the following
guidelines:

Wire gauge:

AWG 26 to AWG 16

Strip length

6.5mm // 0.26 in.

Current rating

10A

Insulation resistance

AC 2000V min

Insulation withstand
voltage

>2000MΩ DC500V

Operation
Temperature

-40ºC to +105ºC