beautypg.com

GW Instek PSW-Series User Manual User Manual

Page 159

background image

APPENDIX

159

Rising current slew rate F-06

72.00A/s (PSW 30-36)
144.0A/s (PSW 30-72)
216.0A/s (PSW 30-108)
27.00A/s (PSW 80-13.5)
54.00A/s (PSW 80-27)
81.00A/s (PSW 80-40.5)
14.40A/s (PSW 160-7.2)
28.80A/s (PSW 160-14.4)
43.20A/s (PSW 160-21.6)
9.000A/s (PSW 250-4.5)
18.00A/s (PSW 250-9)
27.00A/s (PSW 250-13.5)
2.880A/s (PSW 800-1.44)
5.760A/s (PSW 800-2.88)
8.640A/s (PSW 800-4.32)

Falling current slew rate F-07

72.00A/s (PSW 30-36)
144.0A/s (PSW 30-72)
216.0A/s (PSW 30-108)
27.00A/s (PSW 80-13.5)
54.00A/s (PSW 80-27)
81.00A/s (PSW 80-40.5)
14.40A/s (PSW 160-7.2)
28.80A/s (PSW 160-14.4)
43.20A/s (PSW 160-21.6)
9.000A/s (PSW 250-4.5)
18.00A/s (PSW 250-9)
27.00A/s (PSW 250-13.5)
2.880A/s (PSW 800-1.44)
5.760A/s (PSW 800-2.88)
8.640A/s (PSW 800-4.32)

Internal resistance
setting

F-08

0.000Ω

Bleeder circuit control

F-09

1 = ON

Buzzer ON/OFF control F-10

1 = ON

Measurement Average
Setting

F-17

0 = Low

Lock Mode

F-19

0 = Panel lock: allow output off

USB/GPIB setting
Rear Panel USB Mode

F-22

2 = USB CDC

GPIB address

F-23

8