Chapter 8 Features

Changing PM Limit Model Number to PM Express Limit

EZ-ZONE PM Limit firmware revisions of 13 and above allow the user to switch between a PM Limit control

to a PM Express Limit. Switching to a PM Express Limit eliminates the complexity of the PM Limit control

by allowing the user to operate with a simplified menu structure.

Note:

When switching from a Limit control to an Express version, optional PM hardware (even though installed)

and firmware features not available in a PM Express will no longer work. To see exactly what is impacted

by this change, compare the chart below to the ordering information page in this document.

How to Change the Control Model Number to a PM Express

1. Enter Factory Page [FCty] , Calibration Menu [`CAL] via front panel or using EZ-ZONE Configurator

Software.

2. Once there, using the green advance button navigate to the Part Number [``Pn] prompt (lower display).

The upper display will show factory [fCtY] indicating the factory model number as shown on the side of

the control is currently in effect.

3. Push the green advance button one more time where the Public Key [Code] prompt will be displayed in

the lower display and the number [4999] in the upper display.

4. Using the up or down arrow keys enter 2501 and push the green advance button to execute the change.

Note:

As noted above, when switching from an integrated control to an Express version, optional hardware (even

though installed) may no longer work. Also, all settings will be defaulted to that of a PM Express and a re-

set will occur when switched. If switching from a PM Express back to the PM Limit standard or enhanced,

a reset will occur with all settings defaulted as shown in this document for the model as shipped from the

factory.

Note:

After switching the model number to a PM Express this document will no longer apply to the control. Click

on the link that follows to acquire the latest version of the PM PID Express User's Guide.

http://www.watlow.com/literature/manuals.cfm

Once there, simply enter express in the "Keyword" field to find the appropriate document.

PM _ _ _ _ -

EZ-ZONE® Limit Controller

Changes to PM Limit Express

Red-green 7-segment displays

Package Size

No Change

Primary Function

No Change

Power Supply

1

100 to 240VÅ (ac)

2

Changes to 1

3

15 to 36VÎ (dc) and 24VÅ (ac)

4

Changes to 3

Output 1 and 2 Hardware Options

AJ

CJ

EJ

Communications Options

None

- Standard Bus EIA-485 always included - all models

Future Options

None

Output 3 and 4 Hardware Options

Changes to None

Isolated Input Option

B

Changes to Express

Custom Options

AA

Standard EZ-ZONE face plate

No Changes

L

B

A

A

A

A

A

A