Watlow ez-zone, Pm limit controller, Back view slot orientation 1/32 din pm3 – Watlow EZ-ZONE PM User Manual
Page 20: Back view slot orientation 1/8 din vertical pm8, Back view slot orientation 1/8 din horizontal pm9, Back view slot orientation 1/4 din horizontal pm4

Watlow EZ-ZONE
®
PM Limit Controller
•
17
•
Chapter 2 Install and Wire
Terminal Definitions for Slot C .
Slot C Terminal Function
Configuration
98
99
power input: ac or dc+
power input: ac or dc-
all
CC
CA
CB
Standard Bus or Modbus RTU EIA-485 common
Standard Bus or Modbus RTU EIA-485 T-/R-
Standard Bus or Modbus RTU EIA-485 T+/R+
Standard Bus or Modbus
PM _ _ _ _ _-[1] _ _ _ AAA
CF
CD
CE
Standard Bus EIA-485 common
Standard Bus EIA-485 T-/R-
Standard Bus EIA-485 T+/R+
PM _ _ _ _ _-[A, 2 or 3] _ _ _ AAA
B5
D6
D5
digital input-output common
digital input or output 6
digital input or output 5
PM _ _ [2] _ _-_ _ _ _ AAA
PM _ _ [4] _ _-_ _ _ _ AAA
C
A
Power
485 Comms
Dig I/O 5 & 6
Output 1
Output 2
Input 1
Back View
Slot Orientation
1/32 DIN PM3
C
Dig I/O 5 &
6
485 Comms
Power
E
A
Output
2
Output
1
Input
1
B
D
Output
4
Output
3
Communications Car
d
Back View
Slot Orientation 1/8
DIN Vertical PM8
A
Output
2
Output
1
Input
1
B
Output
3
Output
4
D
E
Communications Car
d
C
Dig I/O 5 &
6
485 Comms
Power
Back View
Slot Orientation
1/8 DIN Horizontal PM9
C
Dig I/O 5 &
6
485 Comms
Power
A
Output
2
Output
1
Input
1
B
Output
3
Output
4
Back View
Slot Orientation
1/16 DIN PM6
Note:
Slot B above can also
be configured with a
communications card.
A
Output
2
Output
1
Input
1
B
Output
3
Output
4
D
E
Communications Car
d
C
Dig I/O 5 &
6
485 Comms
Power
Back View
Slot Orientation
1/4 DIN Horizontal PM4