beautypg.com

Communications menu – Watlow EZ-ZONE PM User Manual

Page 62

background image

Watlow EZ-ZONE

®

PM Limit Controller

59

Chapter 6 Setup Page

Setup Page

Dis-

play

Parameter Name

Description

Range

Default

Modbus

Relative

Address

CIP

Class

Instance

Attribute

hex (dec)

Pro-

fibus

Index

Param-

eter ID

Data

Type

&

Read/

Write

[2one]
[Zone]

Global

Zone

Turns Zone LED on or

off based on selection.

[`off]

Off (62)

[``on]

On (63)

On

Instance 1

Map 1 Map 2

- - - -

2350

0x6A (103)

1

0x1A (26)

- - - -

3026

uint

RWES

[Chan]
[Chan]

Global

Channel

Turns Channel LED on

or off based on selection.

[`off]

Off (62)

[``on]

On (63)

On

Instance 1

Map 1 Map 2

- - - -

2352

0x6A (103)

1

0x1B (27)

- - - -

3027

uint

RWES

[d;prs]
[dPrS]

Global

Display Pairs

Defines the number of

Display Pairs.

1 to 10

2

Instance 1

Map 1 Map 2

- - - -

2354

0x6A (103)

1

0x1C (28)

- - - -

3028

uint

RWES

[`d;ti]
[ d.ti]

Global

Display Time

Time delay in toggling

between Display Pairs.

0 to 60

0

Instance 1

Map 1 Map 2

- - - -

2356

0x6A (103)

1

0x1D (29)

- - - -

3029

uint

RWES

[USr;S]
[USr.S]

Global

User Settings Save

Save all of this control-

ler's settings to the

selected set.

[SEt1]

User Set 1 (101)

[SEt2]

User Set 2 (102)

[none]

None (61)

None

Instance 1

Map 1 Map 2

26

26

0x(101)

1

0xE (14)

118

1014

uint

RWE

[USr;r]
[USr.r]

Global

User Settings Re-

store

Replace all of this con-

troller's settings with

another set.

[FCty]

Factory (31)

[none]

None (61)

[SEt1]

User Set 1 (101)

[SEt2]

User Set 2 (102)

None

Instance 1

Map 1 Map 2

24

24

0x65

(101)

1

0xD (13)

117

1013

uint

RWE

[CoM]
[`SEt]
Communications Menu

PCoL]
[PCoL]

Communications 1

Protocol

Set the protocol of this

controller to the proto-

col that this network is

using.

[`Std]

Standard Bus (1286)

[Mod]

Modbus RTU (1057)

Modbus

Instance 1
Map 1 Map 2

2492

2972

0x96 (150)

1

7

- - - -

17009 uint

RWE

`Ad;S]
[ Ad.S]

Communications 1

Standard Bus Address

Set the network address

of this controller. Each

device on the network

must have a unique ad-

dress.

The Zone Display on the

front panel will display

this number.

1 to 16

1

Instance 1
Map 1 Map 2

2480

2960

0x96 (150)

1

1

- - - -

17001 uint

RWE

[Ad;M]
[Ad.M]

Communications (1 or 2)

Modbus Address

Set the network address

of this controller. Each

device on the network

must have a unique ad-

dress.

1 to 247

1

Instance 1

Map 1 Map 2

2482

2962

Instance 2

Map 1 Map 2

2500 2980

0x96 (150)

1

2

- - - -

17007 uint

RWE

Note:
Some values will be rounded off to fit in the four-character display. Full values can be read
with other interfaces.

*

These parameters/prompts are available in this menu with firmware revisions 11.0 and

above.

R: Read

W: Write

E:

EEPROM

S: