beautypg.com

Chapter four, Control reference, App.measure.px.operator (paramengine = "tie") – Teledyne LeCroy WaveExpert series Automation Manual User Manual

Page 250

background image

Chapter Four

Control Reference

This (one of two) time positions, delimits the range of the feature in the TDR signal to be analyzed for
the purpose of estimatingof capacitance and inductance.

CursorTimePos2

From -1.79769e+308 to 1.79769e+308 step 0

Double

Range

Description

TIE

app.Measure.Px.Operator (ParamEngine = "TIE")

TIE is "Time Interval Error", or the error in expected arrival time of trnasotions in either a data stream or a clock signal.
It is the heart of most jitter measurments (where only one signal is under analysis). The Skew processor is closely
related to this function in cases where measurements are using a separate reference clock.

WARNING: The TIE processor is appropriate for analysis of "real-time" acquired waveforms for jitter and timing
variations. It will give incorrect results for equivalent-time type waveforms.

LevelType

Enum

Values

Absolute

Percent

BaseFrequency

Double

DataIsNRZ

Bool

FindBaseFrequency

Action

FindLevel

Action

FrequencyMultiplier

Double

Hysteresis

Double

IncludeVirtualEdges

Bool

IntervalsEdgeEdge

Integer

IntervalType

Enum

LevelType

Enum

MaxComboIntervals

Integer

PercentLevel

Double

SignalType

Enum

Slope

Enum

Summary

String

UseAllEdges

Bool

UseBaseFrequency

Enum

UseMultiEdgeCombos

Bool

UsePLL

Bool

916435 RevA

4-46