Chapter Three

Control Reference

Sets/Queries the title (prefix) to use when naming saved traces. This prefix will have the family
(sequence) number appended to it when forming the filename.

TraceTitle

Any number of characters

String

Range

Description

Sets/Queries the type of source for waveform recall.

RecallFrom

Enum

Description

Values

File

Recall from file on a mass-storage device

Memory

Recall from one of the internal memories (M1..M4)

Sets/Queries the source for recalling waveform data. Used only when recalling from an internal
memory with RecallSource = "Memory".

RecallSource

Enum

Description

Values

M1

M2

M3

M4

Sets/Queries the destination for waveform recall. When the DoRecall action is executed the waveform
will be transferred into this destination trace.

RecallDestination

Enum

Description

Values

M1

M2

M3

M4

3-108