LINEARIZATION BLOCK
8-40
mod sqrt
23 Modified Square Root
Platinum,0.003850
24 Platinum RTD, Alpha 0.003850
Platinum,0.003923
25 Platinum RTD, Alpha 0.003923
Platinum,0.003902
26 Platinum RTD, Alpha 0.003902
Platinum,0.003911
27 Platinum RTD, Alpha 0.003911
Nickel,0.006270
28 Nickel RTD, Alpha 0.006270
13
Set quality bad on calculation error? (SETQBAD) ......................................................... CWR
The result quality can be affected by a calculation error as follows.
NO
0 Result quality is not affected by a calculation error.
YES
1 Quality is set BAD when a calculation error occurs.
14
Input (INPUT) ..................................................................................................................... CWR
The source of the data to be linearized.
value
Fixed initial Floating-Point value for linearizer.
LSP
Floating Point variable is linearization input value.
15
Temperature Scale (SCALE)............................................................................................. CWR
The temperature scale attribute is only used (and is present in the database) when a
thermocouple or RTD type linearization is specified.
FAHRENHEIT 0
Degrees Fahrenheit (C° x 9/5) + 32
CELSIUS
1
Degrees Celsius (F° – 32) x 5/9
RANKINE
2
Degrees Rankine (F°+459.67) or (K° x 9/5)
KELVIN
3
Degrees Kelvin (C°+273.15)
16
Piecewise Table Number (TABLE) ................................................................................... CWR
The occurrence number of the Piecewise Table Block (PW) that is to serve as the linearization
table for this linearization block if the linearization type is piecewise or inverse piecewise. This
attribute is present in the database when piecewise or inverse piecewise is specified.
Input Range Desired? ....................................................................................................... C – –
If the linearization type is linear, square, mod square, square root, or mod sqrt, input ranges
may be configured. The ranges must be configured in pairs. If a range pair is not present, the
default values are 1.0 for high and 0.0 for low.
NO
0
Configured input ranges are not desired. Default values are set. The
input range attributes are not loaded into the database.
YES
1
Configured input ranges is desired. The input range attributes are
loaded into the database and are readable and writeable.
17
Input Range, Bottom (INLO)............................................................................................. CWR
value
Fixed Floating-Point low value of input range for normalization of the
input value.
18
Input Range, Top (INHI) .................................................................................................... CWR
value
Fixed Floating-Point high value of input range for normalization of the
input value.