beautypg.com

Ds1874 sfp+ controller with digital ldd interface – Rainbow Electronics DS1874 User Manual

Page 77

background image

DS1874

SFP+ Controller with Digital LDD Interface

______________________________________________________________________________________

77

Table 02h, Register CFh: DEVICE VER

FACTORY

DEFAULT

DEVICE

VERSION

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE

ACCESS

N/A

MEMORY

TYPE ROM

CFh DEVICE

VERSION

BIT

7

BIT

0

Hardwired connections to show the device version.

FACTORY

DEFAULT

00h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

PW2 or (PW1 and RWTBL246)

MEMORY TYPE

Nonvolatile (SEE)

D0h-D7h 2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT

7

BIT

0

High-Bias Alarm Threshold (HBATH) is a digital clamp used to ensure that the DAC setting for BIAS currents
does not exceed a set value. The table below shows the range of temperature for each byte’s location. The
table shows a rising temperature; for a falling temperature there is 1°C of hysteresis.

D0h

Less than or equal to -8°C

D1h

Greater than -8°C up to +8°C

D2h

Greater than +8°C up to +24°C

D3h

Greater than +24°C up to +40°C

D4h

Greater than +40°C up to +56°C

D5h

Greater than +56°C up to +72°C

D6h

Greater than +72°C up to +88°C

D7h Greater

than

+88°C

Table 02h, Register D0h–D7h: HBATH