beautypg.com

Ds1874 sfp+ controller with digital ldd interface – Rainbow Electronics DS1874 User Manual

Page 64

background image

DS1874

SFP+ Controller with Digital LDD Interface

64

______________________________________________________________________________________

Table 02h, Register A2h–A3h: VCC OFFSET
Table 02h, Register A4h–A5h: MON1 OFFSET
Table 02h, Register A6h–A7h: MON2 OFFSET
Table 02h, Register A8h–A9h: MON3 FINE OFFSET
Table 02h, Register AAh–ABh: MON4 OFFSET
Table 02h, Register ACh–ADh: MON3 COARSE OFFSET

FACTORY

DEFAULT

00h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

PW2 or (PW1 and RWTBL246)

MEMORY TYPE

Nonvolatile (SEE)

A2h, A4h,
A6h, A8h,

AAh, ACh

S S

2

15

2

14

2

13

2

12

2

11

2

10

A3h, A5h,
A7h, A9h,

ABh, ADh

2

9

2

8

2

7

2

6

2

5

2

4

2

3

2

2

BIT

7

BIT

0

Allows for offset control of these voltage measurements if desired. This number is two’s complement.

FACTORY

CALIBRATED

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

PW2 or (PW1 and RWTBL246)

MEMORY

TYPE Nonvolatile

(SEE)

AEh S

2

8

2

7

2

6

2

5

2

4

2

3

2

2

AFh 2

1

2

0

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

BIT

7

BIT

0

Allows for offset control of temperature measurement if desired. The final result must be XORed with BB40h
before writing to this register. Factory calibration contains the desired value for a reading in degrees Celsius.

Table 02h, Register AEh–AFh: INTERNAL TEMP OFFSET