beautypg.com

Ds1874 sfp+ controller with digital ldd interface – Rainbow Electronics DS1874 User Manual

Page 42

background image

DS1874

SFP+ Controller with Digital LDD Interface

42

______________________________________________________________________________________

POWER-ON

VALUE

10h

READ

ACCESS All

WRITE

ACCESS N/A

MEMORY

TYPE Volatile

70h

TEMP HI

TEMP LO

VCC HI

VCC LO

MON1 HI

MON1 LO

MON2 HI

MON2 LO

BIT

7

BIT

0

BIT

7

TEMP HI: High-alarm status for temperature measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.

BIT

6

TEMP LO: Low-alarm status for temperature measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.

BIT

5

VCC HI: High-alarm status for V

CC

measurement.

0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.

BIT

4

VCC LO: Low-alarm status for V

CC

measurement. This bit is set when the V

CC

supply is below the POA trip

point value. It clears itself when a V

CC

measurement is completed and the value is above the low threshold.

0 = Last measurement was equal to or above threshold setting.
1 = (Default) Last measurement was below threshold setting.

BIT

3

MON1 HI: High-alarm status for MON1 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.

BIT

2

MON1 LO: Low-alarm status for MON1 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.

BIT

1

MON2 HI: High-alarm status for MON2 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.

BIT

0

MON2 LO: Low-alarm status for MON2 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.

Lower Memory, Register 70h: ALARM

3