beautypg.com

Ds1874 sfp+ controller with digital ldd interface – Rainbow Electronics DS1874 User Manual

Page 57

background image

DS1874

SFP+ Controller with Digital LDD Interface

______________________________________________________________________________________

57

Table 02h, Register 84h–85h: DAC1 VALUE

FACTORY

DEFAULT

0000h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

(PW2 and DAC1 EN = 0) or (PW1 and RWTBL246 and DAC1 EN = 0)

MEMORY

TYPE Volatile

84h

0 0 0 0 0

0 0

2

8

85h 2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT

7

BIT

0

The digital value used for DAC1 and recalled from Table 07h at the adjusted memory address found in TINDEX.
This register is updated at the end of the temperature conversion.

V

DAC1

=

REFIN

512

DAC1 VALUE

FACTORY

DEFAULT

0000h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

(PW2 and DAC2 EN = 0) or (PW1 and RWTBL246 and DAC2 EN = 0)

MEMORY

TYPE Volatile

86h

0 0 0 0 0

0 0

2

8

87h 2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT

7

BIT

0

The digital value used for DAC2 and recalled from Table 08h at the adjusted memory address found in TINDEX. This
register is updated at the end of the temperature conversion.

V

DAC2

=

REFIN

512

DAC2 VALUE

Table 02h, Register 86h–87h: DAC2 VALUE