beautypg.com

Ds1874 sfp+ controller with digital ldd interface – Rainbow Electronics DS1874 User Manual

Page 71

background image

DS1874

SFP+ Controller with Digital LDD Interface

______________________________________________________________________________________

71

Table 02h, Register C1h: PW_ENB

FACTORY

DEFAULT

03h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

PW2 or (PW1 and RWTBL246)

MEMORY TYPE

Nonvolatile (SEE)

C1h RWTBL46

RTBL1C RTBL2 RTBL1A RTBL1B WPW1 WAUXAU

WAUXBU

BIT

7

BIT

0

BIT

7

RWTBL46: Read and Write Tables 04h, 06h
0 = (Default) Read and write access for PW2 only.
1 = Read and write access for both PW1 and PW2.

BIT

6

RTBL1C: Read Table 01h or Table 05h, Registers F8h–FFh. Table address is dependent on MASK
bit (Table 02h, Register 89h).
0 = (Default) Read access for PW2 only.
1 = Read access for PW1 and PW2.

BIT

5

RTBL2: Read Table 02h except for PW1 value locations (Table 02h, Registers B0h–B3h)
0 = (Default) Read access for PW2 only.
1 = Read access for PW1 and PW2.

BIT

4

RTBL1A: Read Table 01h, Registers 80h–BFh
0 = (Default) Read access for PW2 only.
1 = Read access for PW1 and PW2.

BIT

3

RTBL1B: Read Table 01h, Registers C0h–F7h
0 = (Default) Read access for PW2 only.
1 = Read access for PW1 and PW2.

BIT

2

WPW1: Write Register PW1 (Table 02h, Registers B0h–B3h). For security purposes these registers
are not readable.
0 = (Default) Write access for PW2 only.
1 = Write access for PW1 and PW2.

BIT

1

WAUXAU: Write Auxiliary Memory, Registers 00h–7Fh. All users can read this area.
0 = Write access for PW2 only.
1 = (Default) Write access for user, PW1 and PW2.

BIT

0

WAUXBU: Write Auxiliary Memory, Registers 80h–FFh
0 = Read and write access for PW2 only.
1 = (Default) Read and write access for user, PW1 and PW2.