DS1874

SFP+ Controller with Digital LDD Interface

______________________________________________________________________________________

63

Table 02h, Register 90h–91h: RESERVED

FACTORY

DEFAULT

0000h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

PW2 or (PW1 and RWTBL246)

MEMORY

TYPE Nonvolatile

(SEE)

These registers are reserved.

FACTORY

DEFAULT

00h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

PW2 or (PW1 and RWTBL246)

MEMORY

TYPE Nonvolatile

(SEE)

These registers are reserved.

FACTORY

CALIBRATED

N/A

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

PW2 or (PW1 and RWTBL246)

MEMORY TYPE

Nonvolatile (SEE)

92h, 94h,
96h, 98h,
9Ah, 9Ch

2

15

2

14

2

13

2

12

2

11

2

10

2

9

2

8

93h, 95h,
97h, 99h,
9Bh, 9Dh

2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT

7

BIT

0

Controls the scaling or gain of the FS voltage measurements. The factory-calibrated value produces an FS
voltage of 6.5536V for V

CC

; 2.5V for MON1, MON2, MON4; and 0.3125V for MON3 fine.

Table 02h, Register 92h–93h: VCC SCALE
Table 02h, Register 94h–95h: MON1 SCALE
Table 02h, Register 96h–97h: MON2 SCALE
Table 02h, Register 98h–99h: MON3 FINE SCALE
Table 02h, Register 9Ah–9Bh: MON4 SCALE
Table 02h, Register 9Ch–9Dh: MON3 COARSE SCALE

Table 02h, Register 9Eh–A1h: RESERVED