beautypg.com

Ds1874 sfp+ controller with digital ldd interface – Rainbow Electronics DS1874 User Manual

Page 74

background image

DS1874

SFP+ Controller with Digital LDD Interface

74

______________________________________________________________________________________

Table 02h, Register C6h: LUTTC

FACTORY

DEFAULT

00h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

PW2 or (PW1 and RWTBL246)

MEMORY TYPE

Nonvolatile (SEE)

C6h MODTC

DAC1TC

DAC2TC RESERVED RESERVED RESERVED RESERVED RESERVED

BIT

7

BIT

0

BIT

7

MODTC: Modulation TempCo
0 = Negative TempCo. For a TINDEX below the MODTI value, the 8-bit recalled value from the
MODULATION LUT is stored in the upper 8 bits of the MODULATION register. For a TINDEX greater
than or equal to MODTI, the recalled value is stored in the lower 8 bits of the MODULATION register.
1 = Positive TempCo. For a TINDEX (Table 02h, Register 81h) below the MODTI value (Table 02h,
Register C2h), the 8-bit recalled value from the MODULATION LUT is stored in the lower 8 bits of the
Modulation register. For a TINDEX greater than or equal to MODTI, the recalled value is stored in the
upper 8 bits of the Modulation register.

BIT

6

DAC1TC: DAC1 TempCo
0 = Negative TempCo. For a TINDEX below the DAC1TI value, the 8-bit recalled value from the DAC1
LUT is stored in the upper 8 bits of the DAC1 DAC’s register. For a TINDEX greater than or equal to
DAC1TI, the recalled value is stored in the lower 8 bits of the DAC1 DAC’s register.
1 = Positive TempCo. For a TINDEX (Table 02h, Register 81h) below the DAC1TI value (Table 02h,
Register C3h), the 8-bit recalled value from the DAC1 LUT is stored in the lower 8 bits of the DAC1
DAC’s register. For a TINDEX greater than or equal to DAC1TI, the recalled value is stored in the
upper 8 bits of the DAC1 DAC’s register.

BIT

5

DAC2TC: DAC2 TempCo
0 = Negative TempCo. For a TINDEX below the DAC2TI value, the 8-bit recalled value from the DAC2
LUT is stored in the upper 8 bits of the DAC2 DAC’s register. For a TINDEX greater than or equal to
DAC2TI, the recalled value is stored in the lower 8 bits of the DAC2 DAC’s register.
1 = Positive TempCo. For a TINDEX (Table 02h, Register 81h) below the DAC2TI value (Table 02h,
Register C4h), the 8-bit recalled value from the DAC2 LUT is stored in the lower 8 bits of the DAC2
DAC’s register. For a TINDEX greater than or equal to DAC2TI, the recalled value is stored in the
upper 8 bits of the DAC2 DAC’s register.

BITS

4:0

RESERVED