beautypg.com

TC Electronic Broadcast 6000 User Manual

Page 94

background image

MD 5.1

90

System 6000 MKII Algorithms

Bypass Limiter
Press to Bypass the Limiter section of the 5.1
algorithm.

MD 5.1 algorithm – soft clip page

MD 5.1 algorithm – soft clip page

Soft Clip

Full Range Softclip
Range: -6 dB to Off
Softclipper Threshold setting after the Compres-
sor for the five multiband channels. Threshold
is always relative to 0 dBFS (Not the Reference
Level).

LFE Softclip
Range: -6 dB to Off
Softclipper Threshold setting for the LFE chan-
nel only.

MD 5.1 algorithm – full limit page

MD 5.1 algorithm – full limit page

Threshold
Range: -12 dB to Off
-6 to 0 dB in 0.1 dB increments
-12 to -6 in 0.5 dB increments
Brickwall limiter for the five multiband channels.
Threshold is always relative to 0 dBFS. LED on
each Output meter indicates when Limiter is ac-
tive.

Release
Range: 0.01 to 1.00 seconds
Release time for the Limiter.

Ceiling
Range: -0.10 dB to 0 dB
Fine-tuning parameter setting the Ceiling for the
Limiter.

The Ceiling parameter prevents the Output sig-
nal from exceeding the adjusted Limiter Thresh-
old. It can be used to “hide” overloads to down-
stream equipment, but it does not remove the
distortion associated with an over.

MD 5.1 algorithm –

LFE limiter page

MD 5.1 algorithm – LFE limiter page

LFE Limiter

Threshold
Range: -12 to +3 dB
-6 to + 3 in 0.1 dB increments
-12 to -6 in 0.5 dB increments
Brickwall limiter for the LFE channel. Threshold
is always relative to 0 dBFS. LED on each Output
meter indicates when limiter is active.