TC Electronic Broadcast 6000 User Manual
Page 54

VSS™ 6.1 Reverb
50
System 6000 MKII Algorithms
Early Start
Range: 0 to 100 %
Adjusting the Start time is an efficient way of get-
ting rid of the first reflections that normally color
the source the most. By adjusting the Start time,
the first reflections are discarded but the timing
of the later reflections remain unchanged. There-
fore this adjustment is typically more acousti-
cally precise and useful than a normal Predelay
control.
Early Stop
Range: 0 to 100 %
The Early Stop parameter can reduce the later
reflections in the Early Reflections pattern. When
using large location types this can be a useful
parameter to smooth the overall perception of
the room.