184
18.5.3
Vision Research Camera
Application Start
At application start, the recording does not start automatically.
Configuration Parameter Values
The
PGMSpeed parameter value 1000 is available.
Key Behavior
•
TAKE: this key is operational in any mode.
•
RECORD: the remote beeps if the CAM key refers to an empty block.
•
RECORD: pressing this key while the current block is recording clears all memory
blocks and starts recording on the first one.
•
CLEAR: press this key to delete the current memory block data.
Cue points management
•
When a new ARM/REC command is issued on a block, all its cue points are cleared.
•
If the
Last Cue command cannot access the desired TC-pre-roll, the player remains
on the current cue point.
•
If the
Last Cue command refers to a TC that does not exist anymore, the key beeps
but the OSD still displays the number of the cue that you wanted to go to.
•
Cue points can be marked across several blocks but the recall is limited to the
currently selected block.
Example:
o While recording on memory block 1, mark cue points 1, 2, and 3 on memory
block 1.
o Press TAKE to start recording on block 2 and mark cue points 1, 2, and 3.
o Press TAKE and select memory block 2. The Last Cue command scrolls through
the cue points of block 2.
o To go through cue points of another block, select that block first then press Last
Cue.
•
On OSD, the first information, displayed in white, refers to the cue points on the
playing block while the second information, displayed in red, refers to the recording
block.