MESSAGE ADVISORY ALERTS

Alerts Window Message

Audio Alert

PFD FAN FAIL – The cooling fan for the PFD is inoperative.

None

MFD FAN FAIL – The cooling fan for the MFD is inoperative.
GIA FAN FAIL – The cooling fan for the GIAs is inoperative.

MFD & PFD MESSAGE ADVISORIES

Message

Comments

DATA LOST – Pilot stored data was
lost. Recheck settings.

The pilot profile data was lost. System reverts to default pilot profile and settings.
The pilot may reconfigure the MFD & PFD with preferred settings, if desired.

XTALK ERROR – A flight display
crosstalk error has occurred.

The MFD and PFD are not communicating with each other. The G1000 system
should be serviced.

PFD1 SERVICE – PFD1 needs service.
Return unit for repair.

The PFD and/or MFD self-test has detected a problem. The G1000 system should
be serviced.

MFD1 SERVICE – MFD1 needs
service. Return unit for repair.
MANIFEST – PFD1 software
mismatch. Communication halted.

The PFD and/or MFD has incorrect software installed. The G1000 system should
be serviced.

MANIFEST – MFD1 software
mismatch. Communication halted.
PFD1 CONFIG – PFD1 configuration
error. Config service req’d.

The PFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.

MFD1 CONFIG – MFD1 configuration
error. Config service req’d.

The MFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.

SW MISMATCH – GDU software
version mismatch. Xtalk is off.

The MFD and PFD have different software versions installed. The G1000 system
should be serviced.

PFD1 COOLING – PFD1 has poor
cooling. Reducing power usage.

The PFD and/or MFD is overheating and is reducing power consumption by
dimming the display. If problem persists, the G1000 system should be serviced.

MFD1 COOLING – MFD1 has poor
cooling. Reducing power usage.
PFD1 “KEY” KEYSTK – Key is stuck.

A key is stuck on the PFD and/or MFD bezel. Attempt to free the stuck key by
pressing it several times. The G1000 system should be serviced if the problem
persists.

MFD1 “KEY” KEYSTK – Key is stuck.

CNFG MODULE – PFD1 configuration
module is inoperative.

The PFD1 configuration module backup memory has failed. The G1000 system
should be serviced.

PFD1 VOLTAGE – PFD1 has low
voltage. Reducing power usage

The PFD and/or MFD voltage is low. The G1000 system should be serviced.

MFD1 VOLTAGE – MFD1 has low
voltage. Reducing power usage